Lcd Controller Board

30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB

30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB
30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB
30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB
30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB
30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB
30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB
30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB
30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB
30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB
30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB
30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB

30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB   30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB
30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB. Battery charging control module automatically controls battery charging and discharging to protect battery. Product Name:Digital control charging module.

Suitable for battery:Storage Battery, Lithium battery. By setting the Upper limit voltage volt-HI:UP; Lower limit voltage volt-LI:dn. The relay turns ON and the charger starts charging for the battery when Current battery voltage is less than Lower limit voltage dn. The relay turns OFF and complete an automatic charge when Current battery voltage is more than Upper limit voltage UP. How to enable the time control function?

It will enable time control function by setting parameter OP is not 0 after entering the parameter set menu. OP default parameter is:--:--h, the default does not turn on time control function. After enable Time Control Function(OP is not equal to 0).

Relay will turn ON and the charger starts charging the battery and the system starts timing when Current battery voltage is less than Lower limit voltage dn. Relay will turn OFF and end charging if Current battery voltage is more than Upper limit voltage UP during timing. Relay will turn OFF and end charging if Current battery voltage is less than Upper limit voltage UP but the time(OP) has ended. Relay will keep ON and charging if Current battery voltage is less than Lower limit voltage dn even though the time(OP) has ended. Module will automatically turn off the charging time control function. And flashing H:ER on screen to remind users that time parameter settings are unreasonable. Press any key to stop flashing. Note: Time format: 00:59 (00 is hours, 59 is minutes) The maximum time is 99:59 which is about 100 hours. UART communication and parameter settings.

The system supports UART data upload and parameter setting functions (TTL level). Battery voltage + battery percentage + charging time + charging status.

12.0V, 020%, 00:10, OP. LCD will display'SET' after enter set parameter menu by long press button'SET'. Switch the set parameters by short pressing button SET. Set parameter value by long or short pressing button UP and DOWN.

Repeat step 2 and step 3 if need to set other parameters. Automatically save and exit the setup menu by long press button'SET' after set all parameters.

Long press:keep press button for more than 3second. In the normal display interface. Display the currently set parameters when short press button SET. Switch display charging percentage and charging time when short press button UP. Enable Relay ON or OFF when short press button DOWN.

Relay will OFF and display OFF if disable relay. Set the status of the LCD backlight(L-P) when long press button UP.

OFF:The backlight will keep bright. ON:Backlight will be automatically turned OFF after 5-10second. Long press SET button to enter the parameter settings menu. Voltage percentage = battery voltage/(volt-HI volt-LI). 1pc XY-L30A 30A Lithium Battery Charge Controller.

All our products have been checked and packaged in good condition. Buyers have to pay for the return cost and we pay the cost for reshipping. The item "30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB" is in sale since Saturday, November 14, 2020. This item is in the category "Business & Industrial\Electrical Equipment & Supplies\Electronic Components & Semiconductors\Semiconductors & Actives\Power Regulators & Converters".

The seller is "west_poison" and is located in Shanghai. This item can be shipped to United States, all countries in Europe, all countries in continental Asia, Australia.

  • Brand: Unbranded
  • MPN: Does Not Apply
  • Country/Region of Manufacture: China
  • Manufacturer Part Number: Does not apply
  • UPC: Does not apply


30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB   30A 6-60V Charging Control Module LCD Display Protection Board Lithium BattehAXB